Cautions in Installation If sludge and dust might accumulate, heighten the blower`s base. If sludge accumulates around the motor or blower,it will be difficult for the motor to radiate heat.This might lead to a breakdown or mooto burn itself out.In this case , lay another pipeline(a device as shown in the above drawing) to stir water around the blower so sludge will not stick to it. |
|
Cautions in Inlet and Outlet The inlet muffler should be erected and installed outdoors to avoid taking in damp air from the tank(as shown in drawing [1] ) The inlet muffler should be mstalled at least 1m/m,above the ground in an open area so it can be easily cleaned if dust accumulates.As shown in drawing[2],if the muffler will become very damp,which might rust the blade wheel and casue a breakdown .Avoid such sifuation if possible. The spare set,being stored for a long time ,might gather rust and check. Be sure to turn it on 30 minutes reglarly(weekly). If it is srored in a damp place,turn it on daily. |
|
Major Specifications of Type GWB |
Advantages |
Suitable Places |
Performance Table & Curve Drawing |
Structure & Material list |
Dimensions |
Cautions in installation |